​K Labs mette a tua disposizione i propri Trainers Certificati, i Laboratori Didattici, i Simulatori di Esame, il proprio Test Center e un Tutor a te dedicato per la preparazione all'esame.


Grazie al nostro supporto la percentuale di candidati che ottengono la certificazione al primo tentativo è prossima al 100%.​

fabio-oyxis2kalvg-unsplash (1).jpeg
939869167014516ec34430a26728e18e 2
logo k labs nuovo-white

Rimani aggiornato sulle novità formative.

Lasciaci la tua e-mail!​

Rimani aggiornato sulle novità formative.

Lasciaci la tua e-mail!​



Datacenter, Huawei, batteries, cooling system, monitoring system, dcinfrastructure, powerdistributionsystem, cablingsystem

NewCondition 1300.00
Pre-Order

OBJECTIVES

On completion of this program, the participants will be able to:
(1).Describe the history of the Data Center.
(2).Describe the main issues of data center design and maintenance.
(3).Describe the future development of the data center.
(4).Describe the power distribution structure of FM2000.
(5).Describe the power distribution structure of FM1000.
(6).Describe the power distribution structure of FM800.
(7).Describe the features of UPS2000.
(8).Perform the installation of UPS2000.
(9).Perform the commissioning of UPS2000.
(10).Perform the routine operation and troubleshooting of UPS2000.
(11).Describe the features of UPS5000.
(12).Perform the installation of UPS5000.
(13).Perform the commissioning of UPS5000.
(14).Perform the routine operation and troubleshooting of UPS5000.
(15).Describe the features of Integrated UPS5000.
(16).Perform the installation of Integrated UPS5000.
(17).Perform the commissioning of Integrated UPS5000.
(18).Perform the routine operation and troubleshooting of Integrated UPS5000.
(19).Describe the features of storage battery.
(20).Perform the installation of storage battery.
(21).Perform the routine operation and troubleshooting of storage battery.
(22).Describe the features of Integrated PDU8000.
(23).Describe cooling solutions commonly used in the data center.
(24).Describe Huawei air conditioner products series.
(25).Describe the features of NetCol5000-A and NetCol8000-A.
(26).Perform the installation of NetCol5000-A and NetCol8000-A.
(27).Perform the commissioning of NetCol5000-A and NetCol8000-A.
(28).Perform the troubleshooting of NetCol5000-A and NetCol8000-A.
(29).Describe monitoring system solutions commonly used in the data center.
(30).Describe Huawei monitoring system solution.
(31).Describe the Major hardware products and functions of Huawei monitoring system.
(32).Describe the Software structure and main functions of NetEco.
(33).Create modular DC on NetEco.
(34).Perform the basic operation function of NetEco.
(35).Perform the basic alarm and troubleshooting of NetEco.
(36).Describe the realization of fire system.
(37).Describe the structure and main components of fire system.

PREREQUISITES

At least 2 year Data center facility working experience.

WHO SHOULD ATTEND

Channel and agent engineer

TOPICS

1.General introduction to Data Center Facility
Data Center facility development
Data Center facility main parameters
Data Center facility development trend
Huawei Data Center facility introduction
Huawei Data Center facility solutions introduction
2.Cooling System Solution
Cooling System introduction
Main components of the cooling system introduction
Huawei precision air conditioner product introduction
NetCol5000A and NetCol8000A series product introduction
NetCol5000A and NetCol8000A series product installation and commissioning
NetCol5000A and NetCol8000A series product troubleshooting
NetCol5000C and NetCol8000C series product introduction
NetCol5000C and NetCol8000C series product installation and commissioning
NetCol5000C and NetCol8000C series product troubleshooting
3.Introduction to Other System
Fire extinguishing system introduction
Huawei fire extinguishin system introduction
4.Monitoring System Solution
Mainstream monitoring system structure introduction
Huawei monitoring system structure introduction
Huawei hardware of monitoring system introduction
ECC800 product introduction
NetEco functions introduction
NetEco creation introduction
5.Power Distribution System Solution
FM series product Power distribution structure introduction
UPS2000 series product introduction
UPS2000 series product installation and commissioning
UPS2000 series product troubleshooting
UPS5000 series product introduction
UPS5000 series product installation and commissioning
UPS5000 series product troubleshooting
Battery application and maintenance knowledge
PDU8000 series product introduction
PDU8000 series product troubleshooting

hcip-data-center-facility-deployment
logo k labs nuovo-white

K Labs S.r.l.

Tel. +39 059 821229 | info@klabs.it

P.Iva IT02034520367

PRIVACY E COOKIE

©2024  K LABS Srl - TUTTI I DIRITTI RISERVATI


linkedin

©2024  K LABS Srl - TUTTI I DIRITTI RISERVATI

PRIVACY E COOKIE


linkedin

FOLLOW US

FOLLOW US